2-stage air-cooled starting-air compressors
Type . Technical Data for a final pressure of 30 bar
Final
pressure
Stage Cylinder Speed Fill-up
Capacity
Power-
Consumption
Heat
Dissipation
Weight Dimensions mm
max. bar . . rpm m³/h kW kJ/sec kg Length Width Hight
WP 15 L 40 2 2 1150
1450
1750
12,0
15,0
18,1
2,7
3,4
4,1
3,0
3,7
4,5
120 812 600 630
WP 22 L 40 2 2 1150
1450
1750
16,6
21,0
25,3
3,5
4,4
5,4
3,9
4,8
5,9
135 852 600 630
WP 33 L 35 2 2 1150
1450
1750
25,0
31,5
38,0
5,1
6,5
7,8
5,6
7,1
8,6
145 860 600 630
WP 45 L 40 2 2 1170
1470
1770
40,0
50,0
60,0
7,6
9,6
11,5
8,4
10,6
12,6
310 1210 745 820
WP 65 L 40 2 2 1170
1470
1770
52,0
66,0
80,0
10,2
12,8
15,4
11,2
14,0
17,0
320 1250 745 820
H 25 40 2 2 50
double-
strokes/min
1,8 Hand air
compressor
28 315 230 340

Performance data with 5% tolerance, referred to 20° C and an air pressure of 1013 mbar.

Charging Capacity according to ship building regulations.

Performance data on final pressure deviating from 30 bar will be provided upon request.

Weights and dimensions for standard units with three-phase A. C. motor, IP 54, and flexible mounting.