Water-cooled compressors series WP 5000
Final pressure 350 bar
Type Stage Cylinder Speed Charging Capacity Power required Weight Dimensions mm Frequenzy
  . . U/min m³/h (FAD) kW kg Length Width Hight Hz
WP 5500 4 4 1170
1470
1770
52
65
80
15,3
23,3
28,0
930 970 810 1325 60
50
60
WP 5000 4 4 1170
1470
1770
100
130
160
30,7
46,5
56,0
1650 1215 1095 1570 50
60
50

Performance data with 5% tolerance, referred to 20° C and an air pressure of 1013 mbar.

Charging Capacity according to international navy standards.

Performance data on final pressure deviating from 30 bar upon request.

Weights and dimensions for standard units with three-phase A. C. motor, IP 54, and flexible mounting.

Cooling water requirement referred to a Δ t = 10 K